Ultrasound,Ultrasonic,b scanner,bladder scanner,ECG,Patient Monitor,Ophthalmic,Dentalt,Respirator equipment,Transducer,OCT

      Prouduct list
Ultrasound B Scanner
Ultrasound Color Doppler
Ultrasound Bladder Scanner
Veterinary Ultrasound
Ultrasound Accessories
ECG(Electrocardiograph)
Monitoring/Fetal Doppler
Ophthalmic(UT/OCT)
Other Products
 

 

    Product Show
 Other Products >> Ventilator/Anesthesia >> SV-100C Protable Ventilator
 
    
Number:
11182312616
Name:
SV-100C Protable Ventilator
Spec:
Memo:
Class:
Other Products
 
    Product Readme

 

 Scope

 

 

Use for first aid

Use for ambulance

Use for transport

 
 

 Physical Specifications

 Dimensions

Carrying packages Dimensions Packaging Dimensions

 Width:    300mm

Width:    460mm Width:    620mm

 Depth:    160mm

Depth:    200mm Depth:    240mm

Height:    230mm

Height:    400mm

Height:    410mm

Weight    3Kg

Weight    7Kg

Weight    11Kg

 

 Environmental Specifications

Operating Requirements

Storage/Shipping Requirements

Temperature:            5 to 40oC 

Temperature:            -20 to 70oC 

Relative Humidity:     less than  80%

Relative Humidity:        less than 93%

The atmosphere pressure: 70 to 106 kPa

The atmosphere pressure: 70 to 106 kPa

 Electrical Specifications

Input Voltage Requirements

 AC Voltage:   110V~240V

 DC Voltage:   12V
 Inlet Battery:12V , 2Ah (Can be used for 8 hours)

 Frequency:     50Hz/60Hz

 Power:             2A

 Pneumatic Specifications

Pneumatic Specifications 

Oxygen Inlet

Pressurized Oxygen:   0.4MPa medical oxygen or use 2L oxygen cylinder (Choice of suppliers)

 Performance Specification And Tolerances

 Controls 

    

 Power 

  ON/OFF

 Modes

  CMV(IPPV)   A/C(SIPPV)   SIMV   SPONT  PEEP(Choice of suppliers)

 Tidal Volume   

 50~1200ml

 Breath Rate

 5~60 bpm 

 PEEP 

  0~2KPa 

 O2%  

   45~90% 

Sigh   

1~10 per 100 breath

Peep  

10-60 hpa  (Choice of suppliers)

Trigger Level   

-10~0hpa

Over Pressure Relief   

<6kpa 

  Alarms and Indicators            

 High Pressure Alarm Limit 

2~6kpa    flash, red indicator 

 Low Pressure Alarm Limit   

0.  2~2kpa    Red indicator 

Alarm Silence  

120 sec

  Monitors            

Tidal Volume 

 

 Total Breath Rate    

 

Main Circuit Pressure

 

Wave Display 

Main Circuit Pressure

 What Is Provided            

 Part Name 

Number 

Specification  

  Ventilator 

 1

    

 Oxygen Cylinder

 1

2.5L can be used for 1 hour

 Breath Circuit

 1

1.2m

 Carrying Package

 1

all parts in it

 Breath Value

 1

   

 Mask 

1

   

Charger

1

    

Battery

1

Can be used for 8 hours

Wrench

1

     

Oxygen Pressure Reducer

1

For Nomal Oxygen Cylinder

Lung Simulators

1

   

Hand Book

1

    

CD For Operation

1

   


Hits:3061  UpdateTime:2010/11/18 【Print】 【Close

 

Copyright 2008 Sonostar Electronic  www.sonostar.net  e-mail:sonostar@163.com
Note: Sonostar trademarks is protected by Madrid Treaty.

我要啦免费统计 Please contact me by msn Please contact me by skype Please contact me by yahoo